Magnetical field intensity gauges MH series
Magnetical field intensity gauges MH series are designed for measuring of the magnetic or residual field using the Hall probe.
inkA/morgauss, depending on the model.

MH 05 - Magnetical field intensity gauge
-
- measuring range:
- ±, 0 1,99 kA/m, 0 - 19,9 Gauss
- measuring range:
-
- ±, 0 19,9 kA/m, 0 - 199,9 Gauss
-
- ±, 0 49,9 kA/m, 0 - 499,9 Gauss
- resolution: 10A/m or 0,1 Gaussu
- measured field: alternate (AC), direct (DC) with polarity indication (by switch)
- exceded measure range indication
- manual tangencial Hall effect probe
- weight: 200g including probe and batteries
- dimmensions: 62 x 110 x 27mm
- accurancy class:
± 5 % + 5 dig. of gauge range ± 2 % + 5 dig. of gauge range - battery type: akupack 6 V/750mAh (5xAAA)
- battery level indication: when the battery voltage is low gauge stops measuring and on the display appears "-1" sign
- power consumption: typically 24mA
- temperature operation range: 0-50°C
- comes with case, probe and calibration certificate
MH 06 - Magnetical field intensity gauge

- measuring range: ±, 0 1,99 kA/m, 0 - 19,9 Gauss
- resolution: 10A/m or 0,1 Gaussu
- measured field: direct (DC) with polarity indication
- exceded measure range indication
- manual tangencial Hall effect probe
- weight: 200g including probe and batteries
- dimmensions: 62 x 110 x 27mm
- accurancy class:
± 5 % + 5 dig. of gauge range ± 2 % + 5 dig. of gauge range - battery type: 2 pcs alkaline battery AAA 1,5V
- battery level indication: when the battery voltage is low gauge stops measuring and on the display appears "-1" sign
- power consumption: typically 24mA
- temperature operation range: 0-50°C
- comes with case, probe and calibration certificate
MH 07 - Magnetical field intensity gauge
- measuring range: ±, 0 20 kA/m, 0 - 200 Gauss
- resolution: 10A/m or 0,1 Gaussu
- measured field: direct (DC) with polarity indication
- exceded measure range indication
- manual tangencial Hall effect probe
- weight: 200g including probe and batteries
- dimmensions: 62 x 110 x 27mm
- accurancy class:
± 5 % + 5 dig. of gauge range ± 2 % + 5 dig. of gauge range - battery type: 2 pcs alkaline battery AAA 1,5V
- battery level indication: when the battery voltage is low gauge stops measuring and on the display appears "-1" sign
- power consumption: typically 24mA
- temperature operation range: 0-50°C
- comes with case, probe and calibration certificate
MH - 7.5 Magnetical field intensity gauge
Gauge for measuring the magnetical field intensity on ferromagnetic parts and products in production process or after demagnetization

- measuring range: ± 0-19,9 kA/m
- resolution: 10A/m
- measured field: alternate (AC), direct (DC) with polarity indication (by switch)
- exceded measure range indication
- manual tangencial Hall effect probe
- weight: 200g including probe and batteries
- dimmensions: 62 x 110 x 27mm
- accurancy class:
± 5 % + 5 dig. of gauge range | |
± 2 % + 5 dig. of gauge range |
- battery type: 2 pcs alkaline battery AAA 1,5V
- battery level indication: when the battery voltage is low gauge stops measuring and on the display appears "-1" sign
- power consumption: typically 24mA
- temperature operation range: 0-50°C
- comes with case, probe and calibration certificate
The device can be purchased in two versions - measurements in kA / m and gauss units.