Magnetizing Power Sources
Magnetizing power sources are intended for magnetizing the material by direct passing of AC or DC (HWDC or FWDC) in magnetic particle non-destructive testing and, in case of DUO (dual) power sources, for simultaneous magnetizing by the coil as well. Power sources may be turned on separately or simultaneously.
Standard delivery for all models
- independent control and measurement of current
- output switching on is done manually
- control of current is performed by thyristor controller
- demagnetization is performed automatically whenever the current is switched off
- source is also equipped with a 230 V / 10 A socket for connecting the UV lamp
Optional accessories (for extra charge):
- cables
- footswitch pedal
- magnetizing prods with replaceable zinc tips
- pulse magnetizing with adjustable pulse duration
- pneumatic clamping control for serial testing
- control of nozzle activation for serial testing
- touch panel for complete control of source with automatic settings of parameters according to the product under test
- tatistics of achieved currents and magnetization times
ZP | 600 | 1000 | 1000H | 1500 | 1500H | 2000 | 2000H | 2500 | 2500H | 3000 | 3000H | 4000 | 4000H | 5000 | 5000H | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
max. testing current (with power cables) | |||||||||||||||||
AC effective (true RMS) | A | 600 | 1000 | 1000 | 1500 | 1500 | 2000 | 2000 | 2500 | 2500 | 3000 | 3000 | 4000 | 4000 | 5000 | 5000 | |
AC peak value | A | 852 | 1420 | 1420 | 2130 | 2130 | 2840 | 2840 | 3550 | 3550 | 4260 | 4260 | 5680 | 5680 | 7100 | 7100 | |
HWDC effective | A | 600 | - | 750 | - | 1000 | - | 1300 | - | 2500 | - | 3000 | - | 4000 | - | 5000 | |
HWDC peak value | A | 852 | - | 1500 | - | 2000 | - | 2600 | - | 2500 | - | 4000 | - | 6000 | - | 8000 | |
open circuit voltage | A | 4 | 4,5 | 5 | 5 | 5 | 6 | 5 | 6 | 6 | 7 | 7 | 8 | 8 | 9 | ||
AC demagnetizing | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||||||||
operating parameters: | |||||||||||||||||
type (portable, mobile, stationary) | P | P | M | M | M,S | M,S | M,S | M,S | M,S | M,S | M,S | M,S | M,S | M,S | M,S | M,S | |
power supply | V | 320 | 230 | 400 | 400 | 3x400 | 3x400 | 3x400 | 3x400 | 3x400 | 3x400 | ||||||
socket | A | 16 | 16 | 32 | 32 | 32 | 32 | 32 | 32 | 63 | 63 | 125 | 125 | 125 | 125 | 125 | 125 |
cunsumption at operating current | kVA | 2,6 | 3,5 | 5,7 | 6,9 | 7,8 | 10 | 12 | 13 | 18 | 28 | 41 | |||||
current measuring accuracy | % | ±10 | ±10 | ±10 | ±10 | ±10 | ±10 | ±10 | ±10 | ||||||||
load capacity | % | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | ||||||||
recommended connecting cable (not included) | m | 2,5 | 2,5 | 2x2,5 | 2x2,5 | 2x2,5 | 2x3,0 | 2x3,0 | 2x4,0 | 2x4,0 | |||||||
cable cross section | mm² | 95 | 95 | 95 | 2x70 | 2x95 | 2x95 | 2x120 | 4x95 | 4x120 | |||||||
dimensions | cm | 20x22x44 | 48x66x77 | 48x66x77 | 48x66x77 | 48x66x77 | 68x66x77 | 68x66x77 | 68x66x77 | ||||||||
weigth of the basic version (DUO+30) | kg | 17 | 20 | 50 | 60 | 60 | 70 | 70 | 80 | 80 | 90 | 110 | 120 | 130 | 140 | 150 | 160 |
protection IP | 40 | 40 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 |